UbibotExternalCO2Probe_Specifications

UB-CO2-P1 (Technical specifications)

CO2 Sensor Model SCD30
CO2 Measurement Range 400-10,000 ppm (max. 0-40,000 ppm)
Temperature Range -40°C to 70°C
Humidity Range 0~100%RH
Accuracy CO2: ±(30ppm+3%) (400~10,000ppm)
Temperature ±(0.4°C+1%) (0~50°C)
Humidity ±3%RH (25°C, 0~100%RH)
Power Supply DC 5/12V
Communication Protocol RS485 with Modbus RTU
Protection First-grade lightning protection

UB-CO2-P3 (Technical specifications)

CO2 Sensor Model S8
CO2 Measurement Range 400-2,000 ppm (max. 010,000 ppm)
Accuracy CO2: ±(40ppm+3%) (400~2,000ppm)
Power Supply DC 5/12V
Communication Protocol RS485 with Modbus RTU
Protection First-grade lightning protection

Physical specifications

Material ABS
Dimensions 65*46*29 mm
Cable length 3 meters
Working voltage DC 5-12 V
Standby current ≤20 mA